User`s manual

AW00098504000 Features
Basler ace Camera Link 169
Setting Stacked Zone Imaging Using Direct Register Access
To enable stacked zone imaging via direct register access:
Set the value of the Stacked Zone Imaging Enable register to 1 (true).
To set the Offset X and Width, parameters for the zones:
Set the value of the Offset X register.
Set the value of the Width register.
To set up zone 1:
Enable zone 1 by setting the value of the Stacked Zone Imaging Zone 1 Enable register to 1
(true).
Set the Y offset for zone 1 by setting the value of the Stacked Zone Imaging Zone 1 Offset Y
register.
Set the height for zone 1 by setting the value of the Stacked Zone Imaging Zone 1 Height
register.
Zones 2 through 8 are set up in similar fashion.
For more information about direct register access, see Section 3.2 on page 21.