User`s manual

Image Acquisition Control AW00098504000
128 Basler ace Camera Link
Fig. 38: Use Case 4 - Acquisition Start Trigger On and Frame Start Trigger On
Use Case: Acquisition Start Trigger On and Frame Start Trigger On
The acquisition start trigger is on, and the acquisition start trigger source
is set to software. The user must execute an acquisition start trigger
software command to make the camera exit the "waiting for acquisition
start trigger" acquisition status. Because the acquisition frame count is set
to 3, the camera will re-enter the "waiting for acquisition start trigger"
acquisition status after 3 frame trigger signals have been applied.
The frame start trigger is on, and the frame start trigger source is set to
line 1. The user must apply a frame start trigger signal to line 1 to start
each frame exposure.
Settings: Trigger Mode for the acquisition start trigger = On
Trigger Source for the acquisition start trigger = Software
Acquisition Frame Count = 3
Trigger Mode for the frame start trigger = On
Trigger Source for the frame start trigger = Line 1
Trigger Activation for the frame start trigger = Rising Edge
Time
Acquisition Start
Trigger Software
Command
Executed
Frame Start
Trigger Signal
(applied to line 1)
= a trigger signal applied by the user
= a frame start trigger signal that will be ignored because the camera
is not in a "waiting for frame start trigger" status
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a frame start trigger signal
= frame exposure and readout
= frame transmission