A value in a raw register is simply an integer value with no units. To determine what the actual
setting will be, you must multiply the value in the raw register by the camera’s time base. The
time base on ace cameras is 1 µs.
For example, if you set the Exposure Time Raw register to 1000, the exposure time would be
1000 µs (1000 x 1 µs = 1000 µs).
Apply the appropriate externally generated electrical signal (ExFSTrig signal) to the selected trigger
source.
For more information about direct register access, see Section 3.2 on page 21.