User`s manual

Image Acquisition Control AW00098504000
90 Basler ace Camera Link
7.3.3.3 Frame Start Trigger Delay
The frame start trigger delay feature lets you specify a delay (in microseconds) that will be applied
between the receipt of each hardware frame start trigger signal and when the trigger signal will
become effective.
The frame start trigger delay may be specified in the range from 0 to 10000000 µs (equivalent to
10 s). When the delay is set to 0 µs, no delay will be applied.
If you are parameterizing the camera with Basler pylon, the Trigger Delay Abs parameter will
determine the length of the delay.
If you are parameterizing the camera via direct register access, the Trigger Delay Raw Frame Start
register will determine the length of the delay.
The frame start trigger delay will not operate if the Frame Start Trigger Mode is set
to off or if you are using a software frame start trigger.