User`s manual

Configuring the Camera
4-38 BASLER A620
f
DRAFT
Register Name: Strobe 1 Inquiry
Offset from Base Address: 0x104
Field Bit Description A620f Value
Same definitions and values as Strobe 0 Inq
Register Name: Strobe 2 Inquiry
Offset from Base Address: 0x108
Field Bit Description A620f Value
Same definitions and values as Strobe 0 Inq
Register Name: Strobe 3 Inquiry
Offset from Base Address: 0x10C
Field Bit Description A620f Value
Same definitions and values as Strobe 0 Inq
Register Name: Strobe 0 Control
Offset from Base Address: 0x200
Field Bit Description
Presence Inq 0 Indicates the presence of the Strobe 0 signal control feature.
0 = not available 1 = available
The Strobe 0 control feature is available on the A620f.
This field is read only.
---
1 ... 5 Reserved
On / Off 6 Sets whether the Strobe 0 signal is on or off.
0 = off 1 = on
Default = 0
If this bit is 0, all other fields in this register are read only.
Signal Polarity
7 Sets the polarity of the Strobe 0 signal.
0 = low active 1 = high active
Default = 1
Delay Value
8 ... 19 Sets the delay time for the Strobe 0 signal (see Section 3.10).
The delay value can range from 0 to 4095. The units for the delay are
1/1024 ms. For example, if the delay setting is 100, the delay will be
100/1024 ms (~ 97.7 µs).
Duration Value
20 ... 31 Sets the duration for the Strobe 0 signal (see Section 3.10).
The duration value can range from 0 to 4095. The units for the delay
are 1/1024 ms.