4.4.2.3 Error Status Registers for Feature Control
As defined in the IIDC specification, each field in this register is an error or warning flag for the
corresponding feature control register. If a bit = 1, the mode and/or value of the corresponding
feature control register has an error or warning. If a bit = 0, no error or warning is present. Each
field in this register will be updated whenever the corresponding feature control register is
updated. If a bit = 1, we strongly recommend checking the corresponding control register.
On A620
f cameras, a feature’s bit will become 1 when the feature’s setting is outside the specified
range of allowed settings, that is, the setting is lower than the allowed minimum or higher than the
allowed maximum. If this situation occurs, A620
f cameras will continue image capture and you will
see the undesired effects that result from the setting.
Register Name: Feature Control Error Status High
Offset from Base Address: 0x640
Field Bit Description
Brightness 0 Indicates a brightness control error.
0 = no error present
1 = A setting in the brightness control register (see page 4-23) is out-
side of the allowed range
This field is read only.
Auto Exposure
1 Not used on the A620f. This bit should be ignored.
Sharpness 2 Not used on the A620f. This bit should be ignored.
White Balance 3 Not used on the A620f. This bit should be ignored.
Hue 4 Not used on the A620f. This bit should be ignored.
Saturation 5 Not used on the A620f. This bit should be ignored.
Gamma 6 Not used on the A620f. This bit should be ignored.
Shutter 7 Indicates a shutter control error.
0 = no error present
1 = A setting in the shutter control register (see page 4-24) is outside
of the allowed range
This field is read only.
Gain
8 Indicates a gain control error.
0 = no error present
1 = A setting in the gain control register (see page 4-25) is outside of
the allowed range
This field is read only.
Iris
9 Not used on the A620f. This bit should be ignored.
Focus 10 Not used on the A620f. This bit should be ignored.
Temperature 11 Not used on the A620f. This bit should be ignored.