User`s manual

Configuring the Camera
BASLER A620
f 4-21
DRAFT
Register Name: ISO EN / Continuous Shot
Offset from Base Address: 0x614
Field Bit Description
Continuous Shot
0 When the camera is set for video Format 0, Format 1, Format 2 or For-
mat 7, this field controls the “continuous shot” video transmission
mode.
1 = start “continuous shot” transmission
0 = stop “continuous shot” transmission
Default = 0
---
1 ... 31 Reserved
Register Name: One Shot / Multi Shot
Offset from Base Address: 0x61C
Field Bit Description
One Shot 0 When the camera is set for video Format 0, Format 1, Format 2 or For-
mat 7, this field controls the “one shot” video transmission mode.
1 = transmit one frame of video data
(Field is self cleared after transmission.)
Default = 0
Multi Shot
1 Multi shot is not supported on the A620f.
--- 2 ... 15 Reserved
Count Number 16 ... 31 The count number for multi shot is not supported on the A620f.
Register Name: VMode Error Status
Offset from Base Address: 0x628
Field Bit Description
Status 0 Used only when the camera is set for a standard format (not Format 7).
This field will be updated each time the video format, mode, frame rate
or ISO speed setting is changed. The value in this field indicates
whether the current combination of video format, mode, frame rate and
ISO speed settings is acceptable to the camera.
0 = the combination is OK, image capture can be started
1 = the combination is not OK, image capture can not be started
This field is read only.
---
1 ... 31 Reserved