User`s manual
Configuring the Camera
BASLER A620
f 4-19
DRAFT
4.4.2 Control and Status Registers
The base address for all camera control and status registers is:
Bus ID, Node ID, FFFF F0F0 0000
In each control and status register description, an “Offset from the Base Address” is provided. This
a byte offset from the above base address. The address of a control and status register equals
the above base address plus the indicated offset.
Values are stated in decimal format except when marked 0x. Values marked as 0x (e.g., 0x123)
are in hexadecimal format. Bit 0 in each register is the most significant bit.
4.4.2.1 Control and Status Registers for Basic Camera Operation
Register Name: Current Video Frame Rate / Revision
Offset from Base Address: 0x600
Field Bit Description
Frame Rate /
Revision
0 ... 2 If the camera is set for video Format 0, 1 or 2, this field sets the current
video frame rate.
0 = frame rate 0 4 = frame rate 4
1 = frame rate 1 5 = frame rate 5
2 = frame rate 2 6 = frame rate 6
3 = frame rate 3 7 = frame rate 7
Default = 0
Check Section 3.12 to determine the standard frame rates supported
by the A620f.
If the camera is set for Format 7, the setting in this field is ignored.
If the camera is set for Format 6, this field sets the current revision.
(The A620f does not support Format 6.)
---
3 ... 31 Reserved
Register Name: Current Video Mode
Offset from Base Address: 0x604
Field Bit Description
Mode 0 ... 2 This field sets the current video mode.
0 = mode 0 4 = mode 4
1 = mode 1 5 = mode 5
2 = mode 2 6 = mode 6
3 = mode 3 7 = mode 7
Default = 0
Check Section 3.12 to determine the video modes supported by the
A620f.
---
3 ... 31 Reserved