User`s manual

Configuring the Camera
4-20
BASLER A600f
DRAFT
* These registers are defined in version 1.31 of the IIDC specification.
Offset Name Notes
204h * Strobe_1_Cnt Same definition as Strobe_0_Cnt.
208h *
Strobe_2_Cnt Same definition as Strobe_0_Cnt.
20Ch *
Strobe_3_Cnt Same definition as Strobe_0_Cnt.
L
If a strobe signal is enabled, the signal will only be present on the associated out-
put port when the output port is configured for “strobe.” For example, if the
Strobe_0 signal is enabled, the signal will only be present on physical output port
0 when the port is configured for “strobe”. If the Strobe_1 signal is enabled, the
signal will only be present on physical output port 1 when the port is configured for
“strobe”. Etc.
See Section 5.7.10 for more information about configuring the output ports.