User`s manual
Configuring the Camera
BASLER A600f 4-19
DRAFT
Control and Status Registers for the Strobe Signal Output Function
The base address for the Strobe Signal Output Function control and status registers is:
Bus_ID, Node_ID, FFFF F2F0 0300
The offset field in the table is the byte offset from the above base address.
* These registers are defined in version 1.31 of the IIDC specification.
Offset Name Notes
000h * Srobe_CTRL_Inq The A600f and A600fc support the following strobe
signals:
• Strobe_0
• Strobe_1
• Strobe_2
• Strobe_3
100h *
Strobe_0_Inq The A600f and A600fc support the sub-features for
Strobe_0:
• Presence_Inq
• ReadOut_Inq
• On/Off_Inq
• Polarity_Inq
• Min_Value
• Max_Value
104h *
Strobe_1_Inq Same definition as Strobe_0_Inq.
108h *
Strobe_2_Inq Same definition as Strobe_0_Inq.
10Ch *
Strobe_3_Inq Same definition as Strobe_0_Inq.
200h *
Strobe_0_Cnt Setting On_Off to:
0 = disable Strobe_0 {= default}
1 = enable Strobe_0
Setting Signal_Polarity to:
0 = low active
1 = high active {= default}
The delay value can range from 0 (0x000) to 4095
(0xFFF). The units for the delay are 1/1024 ms. For
example, if the delay setting is 100 (0x064), the de-
lay will be 100/1024 ms (~ 97.7 µs).
The duration value can range from 0 (0x000) to
4095 (0xFFF). The units for the delay are 1/1024
ms.