User`s manual

Configuring the Camera
4-16
BASLER A600f
DRAFT
Control and Status Registers for Format_7, Mode_3
Format_7, Mode_3 is available on A600f monochrome cameras only. The base address for each
Format_7, Mode_3 camera control register is:
Bus_ID, Node_ID, FFFF F1F0 0300
The offset field in each of the tables is the byte offset from the above base address.
* This Color_Coding_Inq register is defined in version 1.31 of the IIDC specification.
Offset Name Notes
000h Max_Image_Size_Inq Hmax = 656, Vmax = 491
The VGA sub-image is positioned in the center of
the full size image.
004h
Unit_Size_Inq Hunit = 1, Vunit = 1
008h
Image_Position Default = (0, 0)
00Ch
Image_Size Default = (Hmax, Vmax)
010h
Color_Coding_ID Default = Mono 8 (ID = 0)
014h
Color_Coding_Inq The A600f supports the following color code in this
mode:
• Mono 8 (ID = 0)
024h *
Color_Coding_Inq Field is not used in this mode.
034h
Pixel_Number_Inq The value of this register depends on the following
registers:
• Image_Size
038h
Total_ By tes _Hi_Inq The value of this register depends on the following
registers:
• Image_Size
• Color_Coding_ID
The value Includes the following data:
• Image data
• Padding bytes
• Data added by any enabled smart features
03Ch
Toyal_Bytes_Lo_Inq See Total_Bytes_Hi_Inq register
040h
Packet_Para_Inq UnitBytePerPacket = 4
MaxBytePerPacket depends on:
• Image_Size
• Color_Coding_ID