User`s manual

Configuring the Camera
BASLER A600f 4-15
DRAFT
* When you lower the bytes per packet setting, the number of bytes needed to transmit a frame
(the packets per frame) will increase. Due to limitations in the DCAM structure, a maximum of
4095 packets per frame is allowed. If you set the bytes per packet too low, the number of
packets per frame will exceed the 4095 packet limit and the camera will not transmit frames
properly.
** The Data_Depth register and Color_Filter_ID register are defined in version 1.31 of the IIDC
specification.
Offset Name Notes
044h Byte_Per_Packet BytePerPacket = set by user *
RecBytePerPacket = 4092 (0xFFC)
048h
Packet_Per_Frame_Inq The value of this register depends on the following
registers:
• Image_Size
• Color_Coding_ID
• Byte_Per_Packet
The value covers the following data:
• Image data
• Padding bytes
• Data added by any enabled smart features
04Ch
Unit_Position_Inq Hposunit = 2
Vposunit = 2
054h **
Data_Depth
Indicates the effective data depth of the pixel in-
formation being transmitted from the camera.
The value of this register depends on the following
registers:
• Color_Coding_ID
In Format _7, Mode_1:
Color_Coding_ID Effective Bits
Data Depth Transmitted
• ID =0 (Mono 8) 8 8
058h **
Color_Filter_ID
Identifies the order of the pixel colors transmit-
ted out of the camera on cameras equipped
with an RGB primary color filter (such as the
Bayer filter used on Basler A600fc cameras).
The A600f supports the following color filter IDs:
• ID = 0 (RG/GB)
• ID = 1 (GB/RG)
• ID = 2 (GR/BG)