User`s manual
Configuring the Camera
4-10
BASLER A600f
DRAFT
* This field is defined in version 1.31 of the IIDC specification.
830h Trigger_Mode Setting On_Off to:
0 = disable trigger use {= default}
1 = enable trigger use
Setting Trigger_Polarity to:
0 = low active {= default}
1 = high active
Setting Trigger_Source * to:
0 = ExtTrig on physical input port 0 {= default}
1 = ExtTrig on physical input port 1
2 = ExtTrig on physical input port 2
3 = ExtTrig on physical input port 3
7 = Software trigger
Setting Trigger_Mode to:
0 = mode 0 (programmable mode)
1 = mode 1 (level mode) {= default}
When an external trigger is used, trigger mode 0
and trigger mode 1 are both valid.
When a software trigger is used, only trigger mode
0 is valid.
The parameter portion of the register is ignored.
Offset Name Notes