User`s manual
Configuring the Camera
BASLER A600f 4-3
DRAFT
4.4 Implemented Standard Registers
A list of all standard registers implemented in A600f appears below.
The base address for all camera control registers is:
Bus_ID, Node_ID, FFFF F0F0 0000
This address is contained in the configuration ROM in the camera unit directory. The offset field
in each of the tables is the byte offset from the above base address.
4.4.1 Inquiry Registers
Camera Initialize Register
Inquiry Register for Video Format
Inquiry Registers for Video Mode
* See Section 3.12.1 for more information on the pseudo YUV 4:2:2 mode
Offset Name Notes
000h Initialize Camera will reset itself, break any state lock, and
re-initialize itself to factory settings.
Offset Name Notes
100h V_Format_Inq The A600f and A600fc support:
• Format_0
• Format_7
Offset Name Notes
180h V_Mode_Inq_0
(Format 0)
In format_0, the A600f supports:
• Mode_1 (320 x 240, pseudo YUV 4:2:2*, 16 bits/pix. avg.)
• Mode_5 (640 x 480, mono, 8 bits/pixel)
In format_0, the A600fc supports:
• Mode_1 (320 x 240, YUV 4:2:2, 16 bits/pixel avg.)
• Mode_3 (640 x 480, YUV 4:2:2, 16 bits/pixel avg.)
• Mode_5 (640 x 480, Y mono, 8 bits/pixel)
19Ch
V_Mode_Inq_7
(Format 7)
In format_7, the A600f supports:
• Mode_0 (656 x 491)
• Mode_3 (656 x 491)
In format_7, the A600fc supports:
• Mode_0 (656 x 490)
• Mode_1 (656 x 490)