User`s manual

Configuring the Camera
4-2
BASLER A600f
DRAFT
4.1 Block Read and Write Capabilities
The camera supports block reads and block writes. If you do a single read or a block read, the
camera will return a 0 for all non-existent registers. If you do a single write to a non-existent
register or a block write that includes non-existent registers, the writes to non-existent registers
will have no effect on camera operation.
Block reads or writes are limited to a payload of 32 quadlets.
4.2 Changing the Video Format setting
Whenever the Current Video Format setting is changed, you must also do the following:
If the Cur_V_Format is changed from Format 7 to Format 0, you must also write the
Cur_V_Mode and the Cur_V_Frm_Rate.
If the Cur_V_Format is changed from Format 0 to Format 7, you must also write the
Cur_V_Mode, the Image_Position, the Image_Size and the Bytes_Per_Packet. (See Section
3.12.2 for more information on setting the Bytes per Packet in Format 7).
4.3 Configuration ROM
The configuration ROM in the A600f is compliant with the DCAM specification V 1.30