User`s manual

Basic Operation & Standard Features
BASLER A600f 3-21
DRAFT
Example
Assume that your AOI is set for 100 columns wide and 110 rows high and that your exposure time
is set for 2000 µs. Also assume that after making all camera settings, you check the
Packet_Per_Frame_Inq register in the control and status registers for Format 7. You find that the
packets per frame with the current settings is 3.
Formula 1:
Max. Frames/s = 579.2
Formula 2:
Max. Frames/s = 2666.7
Formula 3:
Max. Frames/s = 493.1
Formula three returns the lowest value. So in this case, the limiting parameter is the exposure time
and the maximum frame rate would be 493 frames per second.
L
The number of packets per frame depends on the setting of the Format 7
Byte_Per_Packet control register. In this example, we assume that the bytes per
packet is set to the maximum. See Sections 3.12.2 and 3.13.2 for more information.
Max. Frames/s
1
110 2+
()15.28 µs×[]15.28 µs+
----------------------------------------------------------------------------------------=
Max. Frames/s
1
3 125 µs
×
-----------------------------=
Max. Frames/s
1
2000 µs + 28 µs
--------------------------------------------=