User`s manual
Configuring the Camera
BASLER A600
f 4-11
DRAFT
Register Name: PIO Control CSR Inquiry
Offset from Base Address: 0x484
Field Bit Description
PIO Control
Quadlet Offset
0 ... 31 Indicates the quadlet offset from the base address of the initial register
space for the PIO Control and Status Registers (CSR).
All A600f cameras support PIO control.
Register Name: Strobe Output CSR Inquiry
Offset from Base Address: 0x48C
Field Bit Description
Strobe Output
Quadlet Offset
0 ... 31 Indicates the quadlet offset from the base address of the initial register
space for the strobe output Control and Status Registers (CSR).
All A600f cameras support strobe output control.