User`s manual
Smart Features
6-24 BASLER A600
f
DRAFT
Please look at the next page and examine the layout of the control and status register for the
lookup table smart feature. You will notice that the first two quadlets of the register include bits that
allow you to check for this feature’s presence and to enable or disable the feature. These initial
two quadlets are followed by 1024 quadlets. The 1024 quadlets contain the values that make up
the customized lookup table.
L
The lookup table smart feature does not add information to the image data stream
and can be accessed even when the extended data stream feature (see Section
6.7.1) is disabled.
When you enable the lookup table feature, the 1024 quadlets that represent the
lookup table are automatically populated with values based on the current gain and
brightness settings. If you want use a customized lookup table you must:
1. Use the look table feature Control and Status Register (CSR) to enable the
lookup table feature.
2. Use the CSR to load the values for the customized lookup table.
When the lookup table is enabled, changes in the gain and brightness settings will
have no effect on camera operation.
The lookup table feature will work when the camera is set for any valid video format.