User`s manual
Basic Operation and Features
Basler A500
k 3-29
PRELIMINARY
3.3.5 Free-run VGA Mode (A504k Only)
Figure 3-24: Free-run VGA Mode
• Disregarding possible jitter, the duration of the effective exposure is defined by period p (set
by Timer 1).
• Jitter may shorten or extend the effective exposure, i.e.
duration of the effective exposure = (p - 15.8 µs) to (p + 15.8 µs).
• The duration of the effective exposure can only occur in multiples of 15.8 µs microseconds.
Timer 1 must be set to a minimum of 10 µs and to a maximum of 16645 µs.
With very low exposures, use flash light.
Frame
Valid
Line
Valid
Internal
Control
Signal
p = Timer 1
Internal Control Signal Period
34 µs
16087 µs
580 µs
f =
15.8 µs
Integrate
Enabled
p = Timer 1
TIMING CHARTS ARE NOT DRAWN TO SCALE
g =
15.8 µs