User`s manual

Mechanical Considerations
Basler A500
k 5-5
PRELIMINARY
5.4 Mechanical Stress Test Results
Cameras were submitted to an independent mechanical testing laboratory and subjected to the
stress tests listed below. The mechanical stress tests were performed on selected camera models
with standard housings. After mechanical testing, the cameras exhibited no detectable physical
damage and produced normal images during standard operational testing.
Test Standard Conditions
Vibration
(sinusoidal,
each axis)
DIN IEC 60068-2-6
5-8.5 Hz / 1.5 mm_8.5-150 Hz /
10 m/s
2
_1 Octave/Minute
5 repetitions (00:25 h test period)
Shock
(each axis)
DIN IEC 60068-2-27 C 11 ms / 3 shocks / positive
100 m/s
2
11 ms / 3 shocks / negative
Bump
(each axis)
DIN IEC 60068-29
100 m/s
2
11 ms / 100 shocks / positive
100 m/s
2
11 ms / 100 shocks / negative
Table 5-1: Mechanical Stress Tests