User`s manual

Configuring the Camera
4-28 Basler A500k
PRELIMINARY
4.2.7.2 Copy the Work Set into a User Set (Profile Save)
Purpose: To copy the Work Set into one of the 15 User Sets. See section 3.12 for an explanation of
configuration sets.
Type: This is a write only command.
Write Command: Cmd-ID R/W-Flag Data Length Data
0x46 0 1 1 Byte
Response: None
Data Format: Byte 1 An ID that specifies the user set
(see table below).
Set ID Set
0x01 User Set 1
0x02 User Set 2
0x03 User Set 3
0x04 User Set 4
0x05 User Set 5
0x06 User Set 6
0x07 User Set 7
0x08 User Set 8
0x09 User Set 9
0x0A User Set 10
0x0B User Set 11
0x0C User Set 12
0x0D User Set 13
0x0E User Set 14
0x0F User Set 15