User`s manual

Configuring the Camera
4-20 Basler A500k
PRELIMINARY
4.2.4.13 Area of Interest Starting Line
4.2.4.14 Area of Interest Height in Lines
Purpose: To set the starting line for the Area of Interest or to read the current starting pixel setting.
See section 3.10 for details.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0xA8 1 2 -
Response: Cmd-ID R/W-Flag Data Length Data
0xA8 0 2 2 Bytes
Write Command: Cmd-ID R/W-Flag Data Length Data
0xA8 0 2 2 Bytes
Response: None
Data Format: Byte 1 Low byte of the starting pixel setting
Byte 2 High byte of the starting pixel setting
Data Range: The starting line setting can range from 0x0000 to 0x03FF. (Note that the
starting pixel = n +1 where n is the value of the starting pixel setting.)
Purpose: To set the height in lines for the Area of Interest or to read the current height setting. See
section 3.10 for details.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0xAA 1 2 -
Response: Cmd-ID R/W-Flag Data Length Data
0xAA 0 2 2 Bytes
Write Command: Cmd-ID R/W-Flag Data Length Data
0xAA 0 2 2 Bytes
Response: None
Data Format: Byte 1 Low byte of the length in pixel setting
Byte 2 High byte of the length in pixel setting
Data Range: The height in lines setting can range from 0x0002 to 0x0400.