User`s manual
Physical Interface
Basler aviator Camera Link 29
2.9 Output Lines
2.9.1 Voltage Requirements
The following voltage requirements apply to the I/O output VCC (pin 10 of the 12-pin receptacle):
2.9.2 Characteristics
The camera is equipped with one physical output line designated as output line 1. The output line
is accessed via the 12-pin receptacle on the back of the camera.
As shown in the I/O schematic, the output line is opto-isolated. See the previous section for the
recommended operating voltage. The absolute maximum voltage is +30.0 VDC. The maximum
current allowed through an output circuit is 50 mA.
A conducting transistor means a logical one and a non-conducting transistor means a logical zero.
Figure 11 shows a typical circuit you can use to monitor the output line with a voltage signal.
Fig. 11: Typical Voltage Output Circuit
Voltage Significance
< +3.3 VDC The I/O output may operate erratically.
+3.3 to +24 VDC Recommended operating voltage.
+30.0 VDC Absolute maximum; the camera may be damaged if the absolute maximum is exceeded.
Table 7: Voltage Requirements for the I/O Output VCC