User`s manual
Configuring the Camera
4-12
BASLER A102f
DRAFT
Control and Status Registers for Format_7, Mode_1
Format_7, Mode_1 is available on color A102fc cameras only. The base address for each
Format_7, Mode_1 camera control register is:
Bus_ID, Node_ID, FFFF F1F0 0100
The offset field in the table is the byte offset from the above base address.
Offset Name Notes
000h Max_Image_Size_Inq Hmax = 1388, Vmax = 1038
004h
Unit_Size_Inq Hunit = 2, Vunit = 2
008h
Image_Position Default = (0, 0)
00Ch
Image_Size Default = (Hmax, Vmax)
010h
Color_Coding_ID A102fc default =Mono 8
014h
Color_Coding_Inq The A600fc supports the following color codes in
this mode:
• Mono 8 (Raw data)
034h
Pixel_Number_Inq The value of this register depends on the following
registers:
• Image_Size
038h
Total _B yt es _Hi_ In q The value of this register depends on the following
registers:
• Image_Size
• Color_Coding_ID
The value covers the following data:
• Image data
• Padding bytes
03Ch
Total_Bytes_Lo_Inq See TOTAL_BYTES_HI_INQ register
040h
Packet_Para_Inq UnitBytePerPacket = 4
MaxBytePerPacket depends on:
• Image_Size
• Color_Coding_ID