User`s manual
Configuring the Camera
BASLER A101f 4-9
DRAFT
The base address for each Format_7, Mode_2 camera control register is:
Bus_ID, Node_ID, FFFF F1F0 0200
This address is contained in the Format_7 section of the “Inquiry Registers for Video Frame Rate
and Base Address of the Video Mode Command and Status Registers for the Scalable Image Size
Format.” A register has been prepared for each video mode that is Format_7, Mode_x.
The offset field in each of the tables is the byte offset from the above base address.
Video Mode Control and Status Registers for Format_7, Mode_2
Offset Name Notes
200h MAX_IMAGE_SIZE_INQ
204h UNIT_SIZE_INQ
208h IMAGE_POSITION
20Ch IMAGE_SIZE
210h COLOR_CODING_ID
214h COLOR_CODING_INQ
234h PIXEL_NUMBER_INQ
238h TOTAL_BYTES_HI_INQ
23Ch TOTAL_BYTES_LO_INQ
240h PACKET_PARA_INQ
244h BYTE_PER_PACKET
TOTAL_BYTES_LO_INQ / BYTE_PER_PACKET
must be