User`s manual

Exposure Start and Exposure Time Control
Basler sprint Mono Cameras 83
Model Taps Camera Link
Clock Speed
Line Acquisition Mode(s)
spL2048-39km 2 taps 40 MHz Single
spL2048-70km 2 taps 80 MHz Single
spL2048-140km 4 taps
8 taps
80 MHz
40 MHz
Dual
Dual
spL4096-20km 2 taps 40 MHz Single
spL4096-39km 2 taps
4 taps
80 MHz
40 MHz, 80 MHz
Single
Single
spL4096-70km 4 taps
8 taps
80 MHz
40 MHz, 80 MHz
Single
Single
spL4096-140km 8 taps 80 MHz Dual
spL8192-20km 4 taps 40 MHz Single
spL8192-39km 4 taps
8 taps
80 MHz
40 MHz, 80 MHz
Single
Single
spL8192-70km 8 taps 80 MHz Single
Table 10: Combinations of Parameter Settings for the Maximum Specified Line Rate