Exposure Start and Exposure Time Control
76 Basler sprint Mono Cameras
AOI Length is the length of the AOI based on the current AOI length setting (see
Section 6.2 on page 118)
p = 0 if the line stamp feature is not enabled (see Section 6.5 on page 136)
p = 16 when the line stamp feature is enabled
Formula 4 calculates the maximum line rate based on the amount of time it takes to transmit the
pixel data for an acquired line from the camera to the host PC:
Where: CL Clk is the Camera Link clock speed for your camera model as stated in Table 8 on
page 35
Taps is the number of taps being used as determined by the current video data output
mode setting (see Chapter 5 on page 85)
AOI Length is the length of the AOI based on the current AOI length setting (see
Section 6.2 on page 118)
p = 0 if the line stamp feature is not enabled (see Section 6.5 on page 136)
p = 16 when the line stamp feature is enabled
Section 4.3.2 on page 80 includes an example that illustrates how to use these formulas to
determine the maximum allowed line rate.
Once you have determined the maximum allowed line rate, you can easily determine the minimum
allowed line period:
Max Lines / s
CL Clk Taps×
12 Taps×()AOI Length p++
-----------------------------------------------------------------------------=
Min Line Period
1
Max Line Rate
--------------------------------------=