User`s manual
Exposure Start and Exposure Time Control
70 Basler sprint Mono Cameras
Exposure Start Delay
In the ExSync edge controlled and ExSync programmable exposure modes, there is a slight delay
between the rise of the ExSync signal and the actual start of exposure. In the ExSync level
controlled mode, there is a slight delay between the fall of the ExSync signal and the actual start of
exposure. This delay is commonly referred to as an exposure start delay.
The exposure start delay for each mode is as shown in the table below.
Start Delay
ExSync Programmable
ExSync Level Controlled
1.21 µs (± 20 ns)
ExSync Edge Controlled 2.51 µs (± 20 ns)
Table 9: Exposure Start Delay