User`s manual
Line Acquisition Modes
44 Basler sprint Mono Cameras
Fig. 16: Dual Line Acquisition - ExSync Cycle 1
Line A
Line B
Object
Passing
Camera
Movement
Point 4
Point 3
Point 2
Point 1
ExSync Cycle 1
Drawing not to scale
Pixel data for point 1 from
line A is transmitted
from the camera.
Image of point 1
acquired by line A.
Image of point 2
acquired by line B.
Pixel data for
point 2 from
line B is stored
in a buffer.