User`s manual

Physical Interface
26 Basler sprint Mono Cameras
1
Pins 1, 13, 14, and 26 are all tied to Ground inside of the camera.
Pin Number Signal Name Direction Level Function
1, 13, 14, 26
1
Gnd Input Ground Ground for the inner shield of the cable
2 Y0- Output Camera
Link LVDS
Data from the Camera Link transmitter
15 Y0+
3 Y1- Output Camera
Link LVDS
Data from the Camera Link transmitter
16 Y1+
4 Y2- Output Camera
Link LVDS
Data from the Camera Link transmitter
17 Y2+
6 Y3- Output Camera
Link LVDS
Data from the Camera Link transmitter
19 Y3+
5 YClk- Output Camera
Link LVDS
Transmit clock from the Camera Link transmitter
18 YClk+
8 Z0- Output Camera
Link LVDS
Data from the Camera Link transmitter
21 Z0+
9 Z1- Output Camera
Link LVDS
Data from the Camera Link transmitter
22 Z1+
10 Z2- Output Camera
Link LVDS
Data from the Camera Link transmitter
23 Z2+
12 Z3- Output Camera
Link LVDS
Data from the Camera Link transmitter
25 Z3+
11 ZClk- Output Camera
Link LVDS
Transmit clock from the Camera Link transmitter
24 ZClk+
Table 6: Pin Assignments for MDR Connector 2