User`s manual

Troubleshooting and Support
Basler sprint Mono Cameras 207
Repeated pattern of 4
slow orange flashes
One of the following errors is present:
A byte time-out has occurred (see Section 7.3.1.1 on page 200).
Invalid OpCode in a read or write command (see Section 7.3.1 on
page 197).
Incoming data has been discarded since no BFS was included
(see Section 7.3.1 on page 197).
Invalid BCC in a read or write command (see Section 7.3.1 on
page 197).
Invalid address in a read or write command (see Section 7.3.1 on
page 197).
Invalid data length in a read or write command (see Section 7.3.1
on page 197).
An unknown error with the binary read/write command format has
occurred.
6
Repeated pattern of 3
slow orange flashes
The last shading table generation process failed. The flashing will
stop when you successfully complete a generation process or you
reset the camera.
7
Repeated pattern of 2
slow orange flashes
One of the following errors is present:
The maximum allowed line rate has been exceeded (see Section
Section 4.3 on page 74).
ExSync has not changed state for 5 seconds or longer. Check the
cable and the ExSync generating device.
8
(lowest)
LED Description Priority
Table 30: Camera Status Indicators