User`s manual

Configuring the Camera
Basler sprint Mono Cameras 185
Lookup Table Value CSR
Register Base Address: 0x4111
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name: Lookup Table Value Offset: 0x0001 Size: 1 Byte Type: Read/Write
Description: Writing an integer to this field enters a value into the camera’s lookup table at the index currently
specified by the lookup table index CSR.
See Section 6.6 on page 141 for more information about the lookup table feature.
Field Name: Min Offset: 0x0002 Size: 1 Byte Type: Read only
Description: Minimum allowed integer value for a lookup table value.
Field Name: Max Offset: 0x0003 Size: 1 Byte Type: Read only
Description: Maximum allowed integer value for a lookup table value.
Field Name: Increment Offset: 0x0004 Size: 1 Byte Type: Read only
Description: An integer value indicating the increment for the lookup table value.