User`s manual

Configuring the Camera
168 Basler sprint Mono Cameras
Horizontal Binning CSR
Exposure Time Control Mode CSR
Register Base Address: 0x1B00
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read/Write
Description: Writing an integer to this field sets the horizontal binning mode:
0x00 = Horizontal binning disabled
0x01 = Horizontal binning enabled
See Chapter 3.8 on page 59 for more information about the horizontal binning feature.
Register Base Address: 0x1400
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read/Write
Description: Writing an integer to this field sets the exposure time control mode:
0x00 = Free run, programmable
0x02 = Free run, edge controlled
0x04 = ExSync. level controlled
0x05 = ExSync, programmable
0x06 = ExSync, edge controlled
See Section 4.1 on page 67 for a description of the exposure time control modes.