User`s manual

Configuring the Camera
166 Basler sprint Mono Cameras
7.2.2.2 Feature Control and Status Register Details
Camera Link Clock Speed CSR
Video Data Output Mode CSR
Register Base Address: 0x3900
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name: Clock Speed Offset: 0x0001 Size: 1 Byte Type: Read/Write
Description: Writing an integer to this field sets the clock speed for the Camera Link interface:
0x06 = 40 MHz clock speed
0x0e = 80 MHz clock speed
See Section 2.8.4 on page 35 for more information about the Camera Link clock speed.
Register Base Address: 0x1700
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read/Write
Description: Writing an integer to this field sets the video data output mode:
0x01 = 2 Tap 8 Bit Mode
0x03 = 2 Tap 10 Bit Mode
0x05 = 2 Tap 12 Bit Mode
0x10 = 4 Tap 8 Bit Mode
0x11 = 8 Tap 8 Bit Mode
0x12 = 4 Tap 10 Bit Mode
0x13 = 4 Tap 12 Bit Mode
See Chapter 5 on page 85 for a description of the video data output modes.