User`s manual
Configuring the Camera
162 Basler sprint Mono Cameras
FPGA Status Inquiry
The camera has been programmed to detect several error conditions in its field programmable gate
array (FPGA). When an error condition is detected, a flag is set. The FPGA status inquiry register
allows you to read the error flags.
Register Base Address: 0x0C10
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this inquiry register:
0x00 = The register is not available
0x01 = The register is available
Field Name: FPGA Status Offset: 0x0001 Size: 1 Byte Type: Read only
Description: Each bit in this field specifies an error condition (see table below). Bit 0 is the least significant bit.
If a bit is set to 1, the error condition assigned to that bit is present. If the bit is set to 0, the error is
not present.
Bit Description
0 No FPGA firmware available.
1 FPGA firmware is available, but the firmware has failed to load.
2 The camera’s maximum line rate has been exceeded.
(Note: If you are operating the camera in ExSync programmable mode and you trigger
the camera faster than allowed, the camera will automatically ignore any trigger
signals that would cause a max line rate exceeded condition and this bit will not be
set.)
3 There is no ExSync signal.
4Reserved
5Reserved
6Reserved
Reserved
7Reserved