6.7 Imaging Sensor Temperature
The camera is equipped with a temperature sensor that lets you monitor the temperature of the
imaging sensor. You can check the temperature of the imaging sensor with the Camera
Configuration Tool Plus (CCT+) or by using binary read commands from within your own application
to read the camera’s inquiry registers.
With the CCT+
With the CCT+ (see Section 7.1 on page 156), you use the Sensor Temperature parameter in the
Camera Information parameters group to check the temperature of the imaging sensor.
By Reading Inquiry Registers
You check the temperature of the imaging sensor by reading the Temperature field of the Imaging
Sensor Temperature Inquiry Register (see page 163).
See Section 7.2.2 on page 164 for an explanation of Inquiry Registers and Section 7.3.1 on
page 197 for an explanation of using read/write commands.
Note
If the temperature of the imaging sensor rises above 75° C, an
overtemperature error will be declared. See Section 6.9.1 on page 146 for
more information about overtemperature error detection.