User`s manual

Video Data Output Modes
106 Basler sprint Mono Cameras
transmit data for pixel 18. Data stream D2 will transmit data for pixel 19. Data stream D3 will
transmit data for pixel 20. Data stream D4 will transmit data for pixel 21. Data stream D5 will
transmit data for pixel 22. Data stream D6 will transmit data for pixel 23. And data stream D7
will transmit data for pixel 24. The pixel data will be at 8 bit depth.
This pattern will continue until all of the pixel data for line one has been transmitted.
After all of the pixel data for the line has been transmitted, the line valid and data valid bits both
become low indicating that valid pixel data is no longer being transmitted.
Figure 39 on page 110 shows the data sequence when the camera is operating in edge-controlled
or level-controlled exposure mode. Figure 40 on page 111 shows the data sequence when the
camera is operating in programmable exposure mode.