User`s manual

Configuring the Camera
46 Basler IP Camera
Output Pin - Indicates the state of the camera’s digital output pin. If the box is unchecked, the
output is inactive. If the box is checked, the output is active.
If the Output Pin Function parameter is set to "User Output", you can also use the box to set the
state of the output. Check the box to make the output active, and uncheck the box to make the
output inactive.
3.8.2 Serial I/O Tab
Forwarding - Check the Forwarding box to enable serial port
forwarding. When forwarding is enabled, serial commands issued via
TCP/IP over the designated port (see the Port parameter below) will
be forwarded to the serial port.
Baud Rate - Sets the baud rate for the serial port (in bits per second).
Line Configuration - Sets the line configuration for the serial port
in Data Bits, Parity, Stop Bit format. For example, 8N1 means 8 data
bits, no parity, 1 stop bit.
Port - Sets the port to listen to for incoming TCP/IP traffic. If
forwarding is enabled, all traffic will be forwarded to the serial port.
Authentication - If the Authentication box is checked, then a login will be required to access the
serial port.
User Name - Sets the user name for access to the serial port. Up to 15 numbers and/or letters
(upper or lower case) can be used.
Password - Sets the password for access to the serial port. Up to 29 characters can be used. All
standard keyboard characters are valid.
Click the Commit button save any changes you have made to the settings.
Commit