User Manual
MCP Series 
Brushed DC Motor Controllers
MCP Series User Manual
170
MOVE
Syntax
move motor,speed,accel,deccel,position,buffer
• Motor - is a variable, constant or expression that species which motor to access.
• Speed - is a variable, constant or expression that sets the speed to run the motor at.  
• Accel - is a variable, constant or expression that sets the acceleration to use when     
 the motor start its movement.  
• Deccel - is a variable, constant or expression that sets the decceleration to use when   
 the motor stops its movement.  
• Position - is a variable, constant or expression that sets the position for the motor     
 to move to.  
• Buffer - is a variable, constant or expression that determines if the command will be buffered(0) 
or execute immediately(1) overriding any currently running command on the motor.     
Description
The MOVE command is used to control a motor using an encoder with a Position PID control 
algorithm. The user must have tuned the Position PID settings for the motor before using the 
MOVE command. With a properly tuned Position PID accurate absolute movments can be made 
by the motor. Note that multiple Move commands can be chained together by buffering the 
commands. As each command nishes the next will start executing.
;example assumes velocity/position  PID settings are correct for the specied motor
main
  move 0,1000,0,0,1000,0
  pause 2000  ;move should take 1 second then stops for 1 second
  move 0,1000,0,0,-1000,0
  pause 2000  ;move should take 1 second then stops for 1 second
  goto main