User Manual
MCP Series 
Brushed DC Motor Controllers
MCP Series User Manual
161
GETS
Syntax
gets stream,[variable1,...,variableN]
• Stream - is a variable, constant or expression that species which stream to read.
• Variabl1...VariablN - is a list of variables to store the read values in.       
Description
The GETS command is used to read bytes from a data stream and store them in user variables.
Stream Types
USB Virtual Communications Port  0
CAN (CANOpen or raw CAN)    1
TTL UART 2
RS232 UART  3
Example
The example reads 4 bytes from the USB stream and stores them in a long variable:
value var long
main
  gets 0,[value.byte3, value.byte2, value.byte1, value.byte0]
  puts 0,[dec value,13]
end