Data Sheet

MCP26x Dual Channel Motor Controller Data Sheet
(c) 2016 Basicmicro. All Rights Reserved.
12
Bridged Channel Mode
The MCPs dual channels can be bridge to run as one channel effectively doubling its current capability for one motor. Damage will
result if the MCP is not set to bridge channel mode before wiring. Download and install Basicmicro Motion Studio PC utility. Connect
the MCP to the computer using an available USB port. Launch Motion Studio and in general settings check the option to combine
channels. When operating in bridged channel mode the total peak current output is 60 amps. Peak current is directly affected by heat
build up. If adequate cooling is maintained, peak currents can be sustained indenitely.
Bridged Channel Wiring
When bridged channel mode is active the internal driver scheme for the output stage is modied. The output leads must be wired
correctly or damage will result. The motor output wire M1A is bridged to M1B to create one side. Then M2A is bridged to M2B to form
the other side.
MOTOR