User Manual

RoboClaw Series
Brushed DC Motor Controllers
RoboClaw Series User Manual
38
BASICMICRO
Battery Cut O Settings
The RoboClaw is able to protect the main battery by utilizing a battery voltage cut o. The cut o
voltage will vary depending on the size of battery used. The table below shows the battery option
setting with the type of battery it will protect and at what voltage the cuto will kick in. The
battery settings can be set by following the steps below.
1. Press and release the LIPO button. The STAT2 LED will begin to blink out the current
setting.
2. Press SET to increment to the next setting. Press MODE to decrement to the previous
setting.
3. Once the desired setting is selected press and release the LIPO button to save this setting
to memory.
Battery Options
Option Setting Description
1 Disabled 6VDC is the default cut o when disabled.
2 Auto Detect Battery must not be overcharged or undercharge! See Battery Settings.
3 3 Cell 9VDC is the cut o voltage.
4 4 Cell 12VDC is the cut o voltage.
5 5 Cell 15VDC is the cut o voltage.
6 6 Cell 18VDC is the cut o voltage.
7 7 Cell 21VDC is the cut o voltage.
8 8 Cell 24VDC is the cut o voltage.