Service manual
HEAD END
76" Bed Wallsaver
Position without Trapeze
76" Bed Wallsaver
Position with Trapeze or
80" Bed without Trapeze
80" Bed Wallsaver
Position with Trapeze
FOOT END
HEAD END
Finish with
Wallsaver
resting on
floor
Wireform Wallsaver
Bend faces upward
Start with tab held
horizontally
STANDARD WIREFORM WALLSAVER INSTALLATION
WALLSAVER ASSEMBLY
1.  Position the Wireform Wallsaver (Part no. 999-0856-180SP) with bent end 
facing upward and tab ends facing inward as shown at right.
2.  Determine the position desired (see bottom of page).
3.  Gently squeeze the wallsaver tab ends inward toward the center of the 
wallsaver and, holding the tabs parallel with the caster base holes (see 
DETAIL A), slide the tabs into the holes while letting the wallsaver gently 
expand outward.
4.  Turn the wallsaver downward until it rests on the oor (See Detail B).
WALLSAVER REMOVAL
1.  To remove or move the wallsaver to 
a new position, raise the wallsaver 
off the oor until the end tabs are 
horizontal.
2.  Squeeze the ends toward the center 
of the wallsaver until the end tabs 
slide out of the caster base holes.
WALLSAVER POSITIONS
1.  The Zenith 7000 wallsaver features two 
standard positions for easy bed/mattress 
length recongurations - 76" and 80".
2.  For 76" beds, position the wallsaver ends 
in the BACK caster base holes (toward the 
foot end). For 76" beds using an optional 
Trapeze unit, position the wallsaver ends in 
the FRONT caster base holes (toward the 
head end.)
3.  For 80" beds, position the wallsaver ends in 
the FRONT caster base holes (toward the 
head end).
GF Health Products, Inc. - www.grahameld.com  Zenith 7000 Service Manual 999-0843-190E
ZENITH SERIES
11