Instructions

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
Allrights including translationreserved.Reproduction by anymethod,e.g.photocopy,microlming, orthecapturein
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represents the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE. *1465106_V3_0422_02_dm_mh_en
Installation and connection
Observe all safety instructions!
The thermostat features 4 terminals for
cable lugs; please refer to the imprint on the
bottom of the thermostat.
If in doubt, have the installation and
connection done by an expert.
Mode of operation
Within the capillary tube (and sensor tip), which is rmly connected to the
thermostat, there is a liquid that expands when heated. At the end of the capillary
tube inside the thermostat, there is a so-called pressure box that has been
preloaded mechanically via the adjustment shaft.
A heating device activated via switch contact increases the temperature; the liquid
of the respectively installed sensor heats up while expanding at the same time.
Once a certain temperature has been reached, the actuator on the pressure box
will interrupt the power circuit.
The temperature will then drop, and the liquid inside the capillary tube contracts.
Again, once a certain temperature has been reached, the power circuit will be
closed and the whole process starts from the beginning.
The temperature, at which the thermostat interrupts the power circuit, can be
changed via the adjustment shaft.
Since it is not an electronic control, this thermostat does not support the precise
selection of a certain temperature.
The switch contact allows for control towards heating and cooling,
depending which contact of the thermostat is used for the connection
(C + 2 or C + 1).
Disposal
At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines.
Technical data
Operating voltage ................... 110 – 250 V/AC, 50/60 Hz
Contact rating ......................... 16(4) A
Adjusting range ....................... 0 – 90 °C
Switching differential ............... 5±3 °C
Accuracy ................................. ±5 °C
Housing temperature .............. max. 80 °C
Sensor temperature ................ max. 110 °C
Protection type ........................ IP20
Sensor length ......................... 68 mm
Sensor Ø ................................ 6.5 mm
Capillary tube length ............... 1 m
Bending radius ........................ min. 5 mm
Operating conditions ............... 0 to +90 °C, 10 - 90 % RH
Storage conditions .................. -15 to +90 °C, 10 - 90 % RH
Dimensions (L x W x H) .......... 62 x 55 x 54 mm (without ring and sensor)
Weight .................................... 113 g
2
1
C
+
°C
0~3
3~6 6~10 10~18
18~30
30~50
50~80
80~120
120~180
180~250
±0.1 ±0.15 ±0.2 ±0.22
±0.25
±0.3 ±0.35 ±0.4 ±0.45 ±0.6
A
1.5:1
比例重量投影 版本
日期签字更改文件号处数标记
设计
制图
审核
工艺
日期
审定
Ø6.5
1000±50
37
53
6.3
42
Ø1.3
1410
4x
Ø
1.
8
1834
5
1.5
(68)
Ø6
4.6
Ø2
45
°
28
28
4-M4
M6x1.2/2
许温度(MAX) 本体80 温部130℃
入方式 充液
缘耐压
1500VAC.1min
(1800VAC.1s/0.25mA)
缘电阻
DC500V,>100M
触电阻
50m
定电流
定电压
差动
16(4)A
250VAC
5±3
单刀
双掷
表示
温度
上升
接点
形式
器保护等级
控器设定温度
270°
旋转角 C与1#脚断
(0℃)
90±5℃
0° (0°C)
270°
90±C
270°
术要
1.表面不能有脏污刮痕;