Operation Manual

49
Thecircuitexampleshowstheconnectionofadeviceto
theNOoutputoftherelay.Dependingontheconnected
heating or cooling device, the NO connector (closing con-
tact)orNC(openingcontact)mustbeused.
Themaximallypermissibleconnectionvaluesfortheelectricdevice
canbefoundinchapter13.
Openthescrewsofthecontactstripandinsertthewiresuntiltheinsulation
is above the edge of the contact surface in the terminal.Hold in position
andtightenthescrews. Ifyoucannotpushthe wireintotheterminalstrip
farenough,checkthelengthoftheendsplice.Afterassembling,checkand
re-tighten all the screws.
Fastenthecoverwithscrewstofrontofthecontactstrip.
Inserttheswitchinglogicintothewall-mountedfrontpartofhousing.Make
surethatlabelsanddisplayarelegibleandnotinanupsidedownposition.If
thisisthecase,thepartsarenotinpropercontact.Theswitchingsignalsare
transferredfromthelogictothefrontpartofhousingbywayofthreecontacts.
Switchthevoltagesupplybackon.