7. Assembly
Theroomthermostatconsistsoftwopartsthatareheldto-
getherbyclips.Theswitchinglogicwithtemperaturesensor,
displayandcontrolpanelisinthefrontpart.Thesupplybat-
teries(2xAA1.5V,notincluded)areplacedinsidethispart.
Alwayschangebothbatteriesandreplacethemwithtwo
newbatteriesofsamesize,brand,typeandage.
Please pay attention to the correct polarity (plus/+ and
minus/-) when inserting the batteries.
Separatethepartsbycarefullyopeningtheclipsinthewall-mountedpartanddetachingthefront
partwithlogicanddisplay.Youndtheclipsinthemidstattheleftandright.Pressbelowtheclips
andpullonthefrontpartoftheroomthermostat.
• Checkwhethertheplacewhereyouintendtoinstallthethermostathaswiresandcablesunder
itssurface.Thesecangetdamagedbydrilling.
Switch off the main switch and secure against being switched on again. Check that the
wires are volt-free.
• Removetheterminalblockontherearoftherelaypart
and the cover of the screw contacts. Route the cables
(fromtherear)throughtheopeningoftherelaypartbe-
hindit.The“UP”arrowshouldpointtotheceiling.