User manual

25
Wiring
1. Connect the magnetic contacts in series and link them to the N.C. contacts at terminals 1 and 2.
2. Connect the red cable (+) of the piezo siren to terminal 3.
3. Connect terminal 4 to the 12 V DC (+) terminal 5.
4. Connect the black cable (-) of the piezo siren to the 12 V DC (-) terminal 6.
5. Connect the white cable with the grey stripes (+) from the mains adaptor to the 12 V DC (+) terminal 5 and
the white cable (-) to the 12 V DC (-) terminal 6.
6. Set jumpers A, B and C to position 1.
Exterior siren
Magnetic contacts
Window Window Door Window Window
Mains adaptor
Main unit
Internal
siren
Jumper
Mains
adaptor
External siren
Magnetic contacts
Window
Window
Door
Black
Red