User manual

Version 09/12
Compressor 12 V / 17 bar
Item no. 84 18 79
1. Intended use
Thisproductisdesignedforinatingstandardtyresandleisurearticlessuchasballs,dinghies,airmattresses
etc.Powerissuppliedviathe12Vcigarettelightersocketofyourvehicle.
Forsafetyandapprovalpurposes(CE),youmustnotrebuildand/ormodifythisproduct.Ifyouusetheproduct
forpurposesotherthanthosedescribedabove,theproductmaybedamaged.Inaddition,improperusecan
causehazardssuchasshortcircuiting,re,electricshocketc.Readtheinstructionscarefullyandkeepthem.
Makethisproductavailabletothirdpartiesonlytogetherwithitsoperatinginstructions.
2. Delivery content
• Compressor
• 3 x additional adaptor
• Operating instructions
3. Safety instructions
Read the operating instructions carefully and especially observe the safety information.
If you do not follow the safety instructions and information on proper handling in this
manual, we assume no liability for any resulting personal injury or damage to property.
Such cases will invalidate the warranty/guarantee.
Persons / Product
• Thedeviceisnotatoy.Keepitoutofthereachofchildrenandpets.
• Donotleavepackagingmateriallyingaroundcarelessly.Thesemaybecomedangerousplayingmaterial
for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture,
ammablegases,vapoursandsolvents.
• Donotplacetheproductunderanymechanicalstress.
• Ifitisnolongerpossibletooperatetheproductsafely,takeitoutofoperation and protect it from any
accidental use. Safe operation can no longer be guaranteed if the product:
- isvisiblydamaged,
- isnolongerworkingproperly,
- has been stored for extended periods in poor ambient conditions or
- hasbeensubjectedtoanyserioustransport-relatedstresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the
product.
• Also observe the safety and operating instructions of any other devices which are connected to the
product.
• Thecompressormayonlybeoperatedondirect-currentvoltageof12V(suchasviathecigarettelighter
socketofapassengercar).Othervoltageswillcausethecompressortobedestroyed!
• Thecompressorisnotsuitedforthetyresoftrucks,agriculturalvehicles,orsimilar,sincethoserequire
higherinationpressuresandairquantities.
• The maximum operating time is 10 minutes. After use, the compressor must cool down for approx.
5 minutes before it can be used again.
• Do not operate the product when it is unattended.
• Ensurethemaximumpermissiblepressure is not exceeded in the inatedtyresorthedinghy,balletc.
Danger of explosion!
• Duetothehighcurrentdrainthevehiclebatterycanbedischargedbythecompressor,ifthecompressoris
operatedrepeatedlyandoverlongerperiodsoftime.
• Checktheproductpriortoinitialusefordamages;ifyoudeterminetheproductisdamaged,donotoperateit.
Miscellaneous
• Consultanexpertwhenindoubtaboutoperation,safetyorconnectionofthedevice.
• Maintenance, modications and repairs are to be performed exclusively by anexpert orat a qualied
shop.
• If you havequestions which remainunanswered by theseoperating instructions, contactour technical
support service or other technical personnel.
4. Operation
1. Placethecompressoronastable,atsurfacenexttothetyreorleisurearticlethatistobeinated.
2. Release the clamping lever at the end of the air hose.
3. Removethevalvecapandpresstheconnectorrmlyontothetyrevalve.Ifrequired,useattingadaptor
wheninatinganairmattress,adinghy,orsimilar.
4. Close the clamping lever.
5. Plugtheconnectingplugintothe12Vcigarettelightersocketofyourvehicletostartthecompressor.The
compressor’s current consumption is 12 A max.
6. When the required pressure has been reached, remove the connecting plug from the cigarette lighter
socket. Never pull on the cable to disconnect the connecting plug from the cigarette lighter socket.
7. Releasetheclampingleverandremovetheconnector.Closethetyrevalve(e.g.byscrewingthevalve
cap on again).
Forsafety reasonsalwaysleavetheclamping leverreleased(open),whenthecompressoris
not in use.
5. Maintenance and cleaning
• Disconnect the connecting plug from the cigarette lighter socket, before cleaning the product.
• Theoutsideoftheproductshouldbecleanedwithasoftdryclothorbrushonly.Neveruseaggressiveor
chemical cleaning agents, since this might damage the surface of the housing or impair operation.
• Theproductcontainsnopartsthatrequiremaintenancebyyou;neverdisassembletheproduct.
• Only an appropriately qualied person, familiar with the hazards involved and with the applicable
regulations, is permitted to perform repair works/to open the product.
6. Disposal
Electronicdevicesarerecyclablewasteandmustnotbedisposedofinthehouseholdwaste.
Attheendofitsservicelife,disposeoftheproductaccordingtotherelevantstatutoryregulations.
7. Technical data
Operating voltage: 12 V/DC (via cigarette lighter socket)
Current consumption: 12 A max.
Operating pressure: 17 bar / 250 psi max.
Air flow rate: 12 l/min
Piston Ø: 1.6 cm
Air hose length: 50 cm
Connection cable length: 300 cm
Dimensions (W x H x D): 14.5 x 12 x 7 cm
Weight: 510 g
TheseoperatinginstructionsarepublishedbyConradElectronicSE,
Klaus-Conrad-Straße1,D-92240Hirschau/Germany.
Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microlming,orthe
captureinelectronicdataprocessingsystemsrequirethepriorwrittenapprovalbytheeditor.Reprinting,also
in part, is prohibited.
Theoperatinginstructionsreectthecurrenttechnicalspecicationsattimeofprint.
Wereservetherighttochangethetechnicalorphysicalspecications.
© 2012 by Conrad Electronic SE.