Instructions
Care and Cleaning
• Disconnect the product from the mains before each cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Clean the product with a dry, bre-free cloth.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
You thus fulll your statutory obligations and contribute to the protection of the environment.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE. *2226739_V2_0420_02_mxs_m_en
Technical Data
Contact load .............................................. 250 V/AC, 50/60 Hz, 20 A
Control range ............................................. 0 to +120 °C
Temperature for sensor ............................. max. +140 °C
Temperature for thermostat casing ............ max. +120 °C
Accuracy .....................................................±3 °C
Switching hysteresis .................................. 3 ±1.5 °C
Length of capillary tube ............................. approx. 1 m
Bending radius for capillary tube ............... min. 5 mm