17. Technical data
Operating voltage ....................... 12 V/DC
Transmission power.................... < 38.80 dBuA/m @3m
Current consumption .................. Zero signal current ca. 25 mA
Operating current ca. 67 mA (without external card reader)
Relay output contacts ................. N.O. and N.C. (switching output max. 3 A, 24 V/DC)
Recording capacity ..................... Output 1: 500 ID cards or 500 codes
also ID cards and codes mixed (max. 500)
Output 2: 500 codes
Read distance ID cards .............. max. 10 cm
ID card type ................................ EM card 125 KHZ
(e.g. Conrad item no. 1656203, 1656202)
Dimensions (W x H x D) ............. 84 x 129 x 41 mm
Weight ........................................190 g
45